Bigstack

Bigstack

  • Docs

›Installation

Introduction

  • Overview

Installation

  • Control Converged
  • Control
  • Compute node (HCI)
  • Storage node (SDS)
  • NIC configuration

    • Network bonding
    • VLAN
    • VLAN on bonding

    High Availability

    • Network offload
    • Control node
    • Compute node
    • Storage node

Quick Start

  • Get Started

Compute

  • flavors
  • images
  • images(CLI)
  • instances
  • Instance Snapshot

Volumes

  • Volume
  • Snapshots
  • Backup
  • Transfer

Network

  • Internet
  • Private Network(LAN)
  • Router
  • Security Group
  • Floating IP
  • Load Balancers

    • Create a Load Balancer
    • Delete a Load Balancer

DNS

  • Create Public Record
  • Create Private Record

Object Store

  • Object Storage
  • Object Storage (S3 API)

File Store

  • Tenant Share

Identity

  • Create a project
  • Modify Quota
  • Create a User
  • Create a group

Storage

  • Add a disk
  • Remove a disk
  • Prepare disk
  • Remove osd
  • Cache
  • Restful API

Disaster Recovery

  • Start scheduler
  • Full Backup
  • Incremental Backup
  • Cleanup
  • Schedule job
  • Increase quota

Kubernetes

    Instance (VM)

    • Create Template
    • Deploy Cluster
    • Storage Class
    • Workload with L4 LoadBalancer

    Compute Node(HCI)

    • Deploy Cluster
    • Storage Class

Monitoring

  • Host
  • Storage
  • Network
  • Instance
  • Top Hosts
  • Top Instances

Logs

  • Alert
  • Notification

    • Email
    • Slack
  • ELK Stack

Maintenance

  • Startup
  • Shutdown
  • Add/Remove a Harddisk
  • Repair Services
  • Fixpack
  • Update CubeOS
  • Support file
  • Export Instance
  • Create CubeOS snapshot
  • Restore CubeOS with snapshot
  • Remove Compute node
  • Remove Storage node

Download

  • Cloud Image

Operating System

  • CentOS 6 - root disk
  • MS Windows

    • Retrieve password
    • Extend partition

Storage node (SDS) Installation Guide

Prerequisite

Before getting started with Storage node (SDS) installation you will need to prepare a control converged node or control node. Make sure to read through these requirements carefully as a successful deployment of Storage node (SDS) installation depends on it.

What is a Storage node (SDS)

Storage node (SDS) play a roles as stack up SSDs & HDDs to CubeOS Hyperconverged Infrastuctures' storage pool.

Dependency

  • Control Converged node or Control node

Hardware recommendation

  • 4 Core CPU or more
  • 16GB RAM or more
  • 250GB SSD or more (System Drive, RAID 1 recommanded)
  • a lot of SSDs as storage cache pool (RAID 0 recommanded)
  • a lot of HDDs as storage pool (RAID 0 recommanded)

Installation

Choose a setup options - Wizard

First Time Setup Options:
1: Wizard
2: Advanced
Enter index: 1

Accept the EULA

-- Welcome --
Welcome to the Cube Appliance setup wizard.
Using this setup wizard, you can:
* View and accept the Software License Agreement
* Set the appliance password
* View and configure networking

Press Enter to continue.


-- Software License Agreement --
Currently selected language: English
1: Select language for license display
2: Read Bigstack terms
3: Read non-Bigstack terms
4: Proceed to acceptance

Select option: 4


By choosing 'I agree,' you agree that (1) you have had the opportunity to
review the terms of licenses presented above and (2) such terms govern this
transaction. If you do not agree, choose 'I do not agree'.
1: I agree
2: I do not agree

Select option: 1

[Optional]Change the password

(default : admin)

-- Appliance Password --
Password changes are applied immediately.
Password has not been modified.
1: Change password
x: Exit
p: Previous screen
n: Next screen

Select option: 1

- Change Password -
Enter old password: admin
Enter new password:
Confirm new password:
Password successfully changed.

Configure Hostname

-- Host Name Configuration --
Host name: unconfigured
1: Change the host name
x: Exit
p: Previous screen
n: Next screen

Select option: 1


- Change the Host Name -
Enter the new host name: storage01


-- Host Name Configuration --
Host name: storage01
1: Change the host name
x: Exit
p: Previous screen
n: Next screen

Select option: n

[Optional] Configure network bounding

if cable is connected, column [Speed] will present the status else N/A

-- Network Bonding Settings --
--------------------------------------------------
Label          BusID   Driver  State    Speed
--------------------------------------------------
    IF.1   0000:04:00.0    r8169     UP    1000F
--------------------------------------------------
1: Display policy
2: Configure network bonding
x: Exit
p: Previous screen
n: Next screen

Select option: n

[Optional] Create VLAN

-- VLAN Settings --
--------------------------------------------------
Label          BusID   Driver  State    Speed
--------------------------------------------------
    IF.1   0000:04:00.0    r8169     UP    1000F
--------------------------------------------------
1: Display policy
2: Configure vlan network
x: Exit
p: Previous screen
n: Next screen

Select option: n

Configure IP address - IF.1

-- Networking Settings --
--------------------------------------------------
Label          BusID   Driver  State    Speed
--------------------------------------------------
    IF.1   0000:04:00.0    r8169     UP    1000F
--------------------------------------------------
1: Display device status
2: Display policy
3: Configure IF.1
x: Exit
p: Previous screen
n: Next screen

Select option: 3


- Configure IF.1 -
Enter the IPv4 address: 10.32.2.251
Enter the IPv4 subnet mask: 255.255.0.0
Enter the IPv4 default gateway: 10.32.0.254


-- Networking Settings --
--------------------------------------------------
Label          BusID   Driver  State    Speed
--------------------------------------------------
    IF.1   0000:04:00.0    r8169     UP    1000F
--------------------------------------------------
1: Display device status
2: Display policy
3: Configure IF.1
x: Exit
p: Previous screen
n: Next screen

Select option: n

Setting DNS

-- DNS Configuration --
No DNS servers configured.
1: Set DNS server 1
2: Set DNS server 2
3: Set DNS server 3
x: Exit
p: Previous screen
n: Next screen

Select option: 1


- Set DNS Server 1 -
Enter the DNS server IP address: 1.1.1.1


-- DNS Configuration --
DNS server 1: 1.1.1.1
1: Set DNS server 1
2: Set DNS server 2
3: Set DNS server 3
x: Exit
p: Previous screen
n: Next screen

Select option: n

Setting the timezone

[IMPORTANT] all nodes must be on the same zone and make sure all the clock/time are sync'ed

-- Time Configuration --
Time configuration changes are applied immediately.
Time Zone: America/New_York
Date: 12/02/2020
Time: 01:14:19
1: Change the time zone
2: Change the date
3: Change the time
x: Exit
p: Previous screen
n: Next screen

Select option: 1

- Change the Time Zone -
Select a continent or ocean:
1: Africa
2: Americas
3: Asia
4: Atlantic Ocean
5: Australia
6: Europe
7: Pacific Ocean
8: Etc
Enter index: 3
Select a timezone:
1: (UTC+02:00) Asia/Jerusalem
2: (UTC+03:00) Asia/Kuwait
3: (UTC+03:00) Asia/Riyadh
~~~~~~
30: (UTC+08:00) Asia/Taipei
~~~~~~
39: (UTC+12:00) Asia/Kamchatka
Enter index: 30


-- Time Configuration --
Time configuration changes are applied immediately.
Time Zone: Asia/Taipei
Date: 12/02/2020
Time: 14:14:21
1: Change the time zone
2: Change the date
3: Change the time
x: Exit
p: Previous screen
n: Next screen

Select option: n

Configure the role - Option 3: storage

-- Cube Role --
Current role: undef
Current Management: IF.1
Current Domain/Region: default/RegionOne
Current Cube Secret Seed: N/A
1: Change role
x: Exit
p: Previous screen
n: Next screen

Select option: 1


- Change Role -
Select a role:
1: control
2: compute
3: storage
4: control-converged
Enter index: 3
Specify controller hostname: control01
Specify controller IP: 10.32.2.240
Specify management interface: IF.1
Specify storage interface [frontend(,backend)]: IF.1
Specify region ("RegionOne"):
Specify cluster secret seed: bigstack


-- Cube Role --
Current role: storage
Current Controller: control01(10.32.2.240)
Current Management: IF.1
Current Storage: IF.1
Current Domain/Region: default/RegionOne
Current Cube Secret Seed: bigstack
1: Change role
x: Exit
p: Previous screen
n: Next screen

Select option: n

[Optional] High Availability setting

-- Cube High Availability --
Current HA setting: disabled
1: Change HA
x: Exit
p: Previous screen
n: Next screen

Select option: n

Summary

Summary
Password has not been modified.
Host name: storage01
IF.1
    Default interface.
    IPv4 Mode:  Manual
    IPv4 Address:   10.32.2.251
    IPv4 Netmask:   255.255.0.0
    IPv4 Gateway:   10.32.0.254
    IPv6 Mode:  Automatic
DNS server 1: 1.1.1.1
Time Zone: Asia/Taipei
Date: 12/02/2020
Time: 14:14:47
Role: storage
Controller: control01(10.32.2.240)
Management: IF.1
Storage: IF.1
Domain/Region: default/RegionOne
Cube Secret Seed: bigstack
High Availability: disabled
1: Accept the configuration
2: Cancel the configuration
3: Modify the configuration

Select option: 1

*** IMPORTANT: Please wait for the first control node apply policy complete before you continue to next node***

Error message:

Policy changes could not be applied. System must be rebooted.
Press enter to continue:

Please RE-image the nodes, if the error message above is presented and start over the installation progress

Last updated on 12/2/2020
← Compute node (HCI)Network bonding →
  • Prerequisite
    • What is a Storage node (SDS)
    • Dependency
    • Hardware recommendation
  • Installation
    • Choose a setup options - Wizard
    • Accept the EULA
    • [Optional]Change the password
    • Configure Hostname
    • [Optional] Configure network bounding
    • [Optional] Create VLAN
    • Configure IP address - IF.1
    • Setting DNS
    • Setting the timezone
    • Configure the role - Option 3: storage
    • [Optional] High Availability setting
    • Summary
    • Error message: