# Check OSD Status

> In a Ceph storage system, each disk designated for storing data will have an OSD (Object Storage Daemon) created to manage it. Users can follow these steps to check an OSD's status.

In a Ceph storage system, each disk designated for storing data will have an OSD (Object Storage Daemon) created to manage it. Users can follow these steps to check an OSD's status.

## List all OSDs {#list-all-osds}

Use command `storage > list_osd` to list all OSDs in the Ceph storage cluster.

```bash
cc2> storage list_osd
     OSD    STATE             HOST        DEV             SERIAL   POWER_ON    USE REMARK
       2       ok              cc1       sdb3 PHDV829200KG800CGN  2187 days    20%
       3       ok              cc1       sdb4 PHDV829200KG800CGN  2187 days    19%
       0       ok              cc1       sdc3 BTWA6326019F800HGN  2940 days    12%
       1       ok              cc1       sdc4 BTWA6326019F800HGN  2940 days    23%
       4       ok              cc1       sdd3 BTWA6326017L800HGN  2938 days    16%
       5       ok              cc1       sdd4 BTWA6326017L800HGN  2938 days    17%
       6       ok              cc2       sdb3 BTWA632602Q3800HGN  2900 days    19%
       7       ok              cc2       sdb4 BTWA632602Q3800HGN  2900 days     0%
       8       ok              cc2       sdc3 BTWA6326030T800HGN  2939 days    20%
       9       ok              cc2       sdc4 BTWA6326030T800HGN  2939 days    26%
      10       ok              cc2       sdd3 BTWA632603GR800HGN  2939 days    21%
      11       ok              cc2       sdd4 BTWA632603GR800HGN  2939 days    18%
      12       ok              cc3       sdb3 BTWA63250476800HGN  2899 days    22%
      13       ok              cc3       sdb4 BTWA63250476800HGN  2899 days    14%
      16       ok              cc3       sdc3 BTWA63260583800HGN  2939 days    18%
      17       ok              cc3       sdc4 BTWA63260583800HGN  2939 days    23%
      14       ok              cc3       sdd3 BTWA632601X9800HGN  2900 days    16%
      15       ok              cc3       sdd4 BTWA632601X9800HGN  2900 days    13%
```

:::info
Column `REMARK` would show whether the disk is encrypted or not. An example shown below.
:::

```bash
cc3> storage list_osd
     OSD    STATE             HOST        DEV             SERIAL   POWER_ON    USE REMARK
       4       ok              cc1       sda3       183222E1E59A  1165 days     2%
       5       ok              cc1       sda4       183222E1E59A  1165 days     2%
       0       ok              cc1       sdc3 PHYM809401PZ480BGN  1642 days     2%
       1       ok              cc1       sdc4 PHYM809401PZ480BGN  1642 days     3%
       2       ok              cc1       sdd3 BTYF91230BVA960CGN  1281 days     2%
       3       ok              cc1       sdd4 BTYF91230BVA960CGN  1281 days     2%
       6       ok              cc2       sda3 PHYM809401GY480BGN  1347 days     2%
       7       ok              cc2       sda4 PHYM809401GY480BGN  1347 days     2%
       8       ok              cc2       sdb3 BTYF91230FHD960CGN  1277 days     2%
       9       ok              cc2       sdb4 BTYF91230FHD960CGN  1277 days     2%
      10       ok              cc2       sdc3 PHYM809301WD480BGN  1860 days     2%
      11       ok              cc2       sdc4 PHYM809301WD480BGN  1860 days     2%
      12       ok              cc3       sdb3 PHYM809401PY480BGN  1735 days     3%
      13       ok              cc3       sdb4 PHYM809401PY480BGN  1735 days     2%
      14       ok              cc3       sdc3 PHYM809401LJ480BGN  1389 days     1%
      15       ok              cc3       sdc4 PHYM809401LJ480BGN  1389 days     2%
      16       ok              cc3        sdd BTYF91230FJX960CGN  1377 days     2% LUKS2-encrypted
```

## Get details of a specific OSD {#get-details-of-a-specific-osd}

Use command `storage > list_osd [OSD_ID]`

```bash
cc2> storage list_osd 3
  overall-health self-assessment test result: PASSED
  ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
    5 Reallocated_Sector_Ct   0x0032   100   100   000    Old_age   Always       -       0
    9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       52522
  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       183
  170 Available_Reservd_Space 0x0033   100   100   010    Pre-fail  Always       -       0
  171 Program_Fail_Count      0x0032   100   100   000    Old_age   Always       -       0
  172 Erase_Fail_Count        0x0032   100   100   000    Old_age   Always       -       0
  174 Unsafe_Shutdown_Count   0x0032   100   100   000    Old_age   Always       -       160
  175 Power_Loss_Cap_Test     0x0033   100   100   010    Pre-fail  Always       -       15950 (476 1231)
  183 SATA_Downshift_Count    0x0032   100   100   000    Old_age   Always       -       0
  184 End-to-End_Error        0x0033   100   100   090    Pre-fail  Always       -       0
  187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
  190 Temperature_Case        0x0022   069   064   000    Old_age   Always       -       31 (Min/Max 22/36)
  192 Unsafe_Shutdown_Count   0x0032   100   100   000    Old_age   Always       -       160
  194 Temperature_Internal    0x0022   100   100   000    Old_age   Always       -       31
  197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
  199 CRC_Error_Count         0x003e   100   100   000    Old_age   Always       -       0
  225 Host_Writes_32MiB       0x0032   100   100   000    Old_age   Always       -       701123
  226 Workld_Media_Wear_Indic 0x0032   100   100   000    Old_age   Always       -       3010
  227 Workld_Host_Reads_Perc  0x0032   100   100   000    Old_age   Always       -       54
  228 Workload_Minutes        0x0032   100   100   000    Old_age   Always       -       3151277
  232 Available_Reservd_Space 0x0033   100   100   010    Pre-fail  Always       -       0
  233 Media_Wearout_Indicator 0x0032   098   098   000    Old_age   Always       -       0
  234 Thermal_Throttle        0x0032   100   100   000    Old_age   Always       -       0/0
  241 Host_Writes_32MiB       0x0032   100   100   000    Old_age   Always       -       701123
  242 Host_Reads_32MiB        0x0032   100   100   000    Old_age   Always       -       852820
  243 NAND_Writes_32MiB       0x0032   100   100   000    Old_age   Always       -       4645947

  HDD Device  0: /dev/sdb
  HDD Model ID : INTEL SSDSC2BB800G7
  HDD Serial No: PHDV829200KG800CGN
  HDD Revision : N2010121
  HDD Size     : 763098 MB
  Interface    : SAT Standard USB/ATA
  Temperature  : 31 °C
  Highest Temp.: 36 °C
  Health       : 98 %
  Performance  : 100 %
  Power on time: 2188 days, 10 hours
  Est. lifetime: more than 98 days
  Total written: 21.40 TB
    The status of the solid state disk is PERFECT. Problematic or weak sectors were not found.
    The health is determined by SSD specific S.M.A.R.T. attribute(s):  #233 Media Wearout Indicator

      OSD    STATE             HOST        DEV             SERIAL   POWER_ON    USE REMARK
        3       ok              cc1       sdb4 PHDV829200KG800CGN  2188 days    17%
```